Craftsman 82174 Owner's Manual

Browse online or download Owner's Manual for Multimeters Craftsman 82174. Craftsman 82174 Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 43
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Owner's Manual
JCRAFTSMAN I
Digital MultiMeter
Model No. 82140
and
Voltage Detector
Model No. 82174
CAUTION: Read, understand and
follow Safety Rules and Operating
Instructions in this manual before
using this product.
Safety
Operation
Maintenance
EspaSol
© Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.craftsman.com 070606
Page view 0
1 2 3 4 5 6 ... 42 43

Summary of Contents

Page 1 - JCRAFTSMAN I

Owner's ManualJCRAFTSMAN IDigital MultiMeterModel No. 82140andVoltage DetectorModel No. 82174CAUTION: Read, understand andfollow Safety Rules and

Page 2

e] ".,l=1t.,f-I III_JellI__."11IIt.|l[_l i [e]__JWARNING: Risk of electrocution. High-voltage circuits, both AC and DC, Jare very dangerous

Page 3

AC VOLTAGE MEASUREMENTSWARNING: Risk of Electrocution. The probe tips may not be longenough to contact the live parts inside some 240V outlets forappl

Page 4

DC CURRENT MEASUREMENTSI CAUTION: Do not make current measurements on the 10A scale forIlonger than 30 seconds. Exceeding 30 seconds may cause damage

Page 5 - IwARN'NGI

RESISTANCE MEASUREMENTSI ARNING: To avoid electric shock, disconnect power to the unit undertest and discharge all capacitors before taking any resist

Page 6

DIODETEST1. InserttheblacktestleadbananaplugintothenegativeCOMjackandtheredtestleadbananaplugintothepositivediodejack.2. Turntherotaryswitchtothe_ / o

Page 7

IWARNING:Toavoidelectricshock,disconnectthetestleadsfromanysourceofvoltagebeforeremovingthebackcoverorthebatteryorfusedoors.IWARNING:Toavoidelectricsh

Page 8

REPLACING THE BATTERIESl WARNING: To avoid electric shock, disconnect the test leads from anysource of voltage before removing the battery door.I1. Wh

Page 9

I/ _,{olUJ;] III:(_,,1:[olO]l i I_[_There may be times when your meter does not operate properly. Here aresome common problems that you may have and s

Page 10

Owner's ManualCRAFTSMANVoltage Detector Model No. 82174I AUTION: Read, understand and follow Safety Rules and OperatingInstructions in this manua

Page 11

WARNING: USE EXTREME CAUTION IN THE USE OF THISDEVICE. Improper use of this device can result in injury or death.Follow all safeguards suggested in th

Page 12

II:_ :] ! :[o] |o[o] _/ / :1_/ _WarrantySafety InstructionsSafety SymbolsControl and JacksSymbols and AnnunciatorsSpecificationsBattery InstallationOp

Page 13

VoltageSensitivityFrequencyDetection distanceOver voltageOperating TemperatureStorage TemperatureHumidityAltitudeBatteryDimensions/WeightSafety100 to

Page 14 - DIODETEST

I WARNING:Toavoidelectricshock,donotoperatethemeteruntiltheIbattery cover is in place and fastened securely.IWARNING: Risk of Electrocution. High-volt

Page 15

Manual del propietarioMultimetro DigitalModelo No. 82140Detector de voltajeModelo No. 82174PRECAUCION: Lea, comprenda ysiga las Reglas Seguridad eInst

Page 16

Ir:1:] IIr:l e]:l[o_o]_III1:1_IIeIqGarantiaInstrucciones de SeguridadSefiales de SeguridadControl y ConectoresSimbolos y AnunciadoresEspecificacionesI

Page 17 - 1-888-326-1006

_____ _ __ o_A" __ "o_ __ h. oGARANTiA COMPLETA POR UN ANO PARA EL MULiMETRO DEESCALA MANUAL DE CRAFTSMANSi este Multimetro de escala manual

Page 18 - CRAFTSMAN

Este medidor ha sido disefiado para uso seguro, sin embargo debe seroperado con precauci6n. Para una operaci6n segura, debera cumplir lasreglas enumer

Page 19

;']:1_r:11:_"!J]:1."]:[rltJ_11J7:1,L ADVERTENCIA ]I RECAUCION Ir500VmmEsta seSal adyacente a otra seSal, terminal odispositivo en opera

Page 20 - VoltageSensitivity

_o] _II/ _,To]III:F:i'lo_o] _I:[O,]lI[O]_,,1:F:1 Pantalla LCD2 Selector de FunciSn3 Enchufe COM4 Enchufe 10A5 Enchufe positivoNota: El soporte in

Page 21

_".)-..,1=[e,]I_1[___[e,][e]_I_Funci6nVoltaje CD(V CD)Voltaje CA(V CA)Corriente CD(A CD)ResistenciaPRUEBA DEBATERiAEscala200mY2000mY20V200V600V20

Page 22 - Detector de voltaje

_-,.)_ =[e,]I_1[e,7'__T_e,][el ZI=[_.".)Prueba de diodo Corriente de prueba de 1mA m&xima, voltajede circuito abierto 2.8V DC tipicaVeri

Page 23

ONEYEARFULLWARRANTYONCRAFTSMANMANUALRANGINGMULTIMETERIfthisCRAFTSMANManualRangingMultiMeterfailstogivecompletesatisfactionwithinoneyearfromthedateofpu

Page 24

J ADVERTENClA: Para evitar choque electrico, desconecte los cables de Jprueba de cualquier fuente de voltaje antes de quitar la tapa de laIbateria.1.

Page 25

k, _ Ok, | O" ___ Ok,I ADVERTENClA: Riesgo de electrocuci6n. Los circuitos de alta tensi6n,tanto de CA y CD, son muy peligrosos y deberan ser med

Page 26

Lapantallaindicaraelvalorypuntodecimalcorrecto.Siseinviertelapolaridad,lapantallaindicara(-)menosantesdelvalor.MEDIClONDEVOLTAJECAADVERTENClA:Riesgode

Page 27

MEDICION DE CORRIENTE CDPRECAUCION: no haga mediciones de corriente en la escala de 10 Adurante mas de 15 segundos. Si la medici6n se extiende a mas d

Page 28

MEDIDAS DE RESISTENCIAADVERTENCIA: Para evitar choque electrico, desconecte la tensi6na la unidad bajo prueba y descargue todos los capacitores antes

Page 29

PRUEBADE DIODO1, Inserte el cable negro de prueba en el enchufenegativo COM y el cable rojo de prueba en elenchufe positivo de diodo.2. Gire el select

Page 30 - Ibateria

rAV:1_ii :1_1hVd1:1_i I_lI ADVERTENClA: Para evitar choque electrico, desconecte los cablesde prueba de cualquier fuente de voltaje antes de quitar la

Page 31

REEMPLAZO DE LAS BATERiASI DVERTENCIA: Para evitar choque electrico, desconecte los cables deprueba de cualquier fuente de voltaje antes de quitar la

Page 32

REEMPLAZO DE LOS FUSIBLESI ADVERTENCIA: Para evitar choque electrico, desconecte los cablesde prueba de cualquier fuente de voltaje antes de quitar la

Page 33

_o] Rt[oKo]_I J]:1 :,1_,{o]:] 1:1;_r:_:Habra ocasiones en que su medidor no funcione correctamente. Enseguida encontrara algunos problemas comunes que

Page 34

Thismeterhasbeendesignedforsafeuse,butmustbeoperatedwithcaution.Theruleslistedbelowmustbecarefullyfollowedforsafeoperation.1. NEVERapplyvoltageorcurre

Page 35 - PRUEBADE DIODO

Manual del usuarioNDetector de voltaje ModeloNo.82174© Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.www.sears.com/craftsman 121103IPRECAUCI

Page 36

ADVERTENCIA: EXTREME SUS PRECAUCIONES AL USAR ESTEIDISPOSITIVO. El uso inadecuado de este dispositivo puede resultar en Ilesiones o la muerte. Siga la

Page 37

=[...",]".,I=[o,,)I_1[o,T±[o,,)[o] _I =[.._Sensibilidad de VoltajeFrecuenciaDistancia de detecci6nSobre voltajeTemperatura de operaci6nTempe

Page 38

I ADVERTENClA: Para evitar choque electrico, no opere el medidor hastaIque la tapa de la bateria esta colocada y asegurada.Ih. _. Oh. II O" _._ O

Page 39

.-"9'_"__I:IIIk'dl,,"]k'd_"+I:[o] n_IwARN'NGII CAUTIONI[-MAX500VmmThis symbol adjacent to another symbol, term

Page 40 - Manual del usuario

o_o]_IIII_,To]L',]F:I _Ie]LnlT:T_[_:1. LCD Display2. Function switch3. COM jack4. 10A jack5. Positive jackNote: Tilt stand, fuse and batterycompa

Page 41

FunctionDCVoltage(VDC)ACVoltage(VAC)DCCurrent(ADC)ResistanceBatteryTestRange200mV2000mV20V200V600V200V600V2000#A20mA200mA10A200£22000£220k£!200k£!2000

Page 42 - __ __ e_ = __ _ __ t, __

Diode TestContinuity CheckBattery Test currentInput ImpedanceACV BandwidthDCA voltage dropDisplayOverrange indicationPolarityMeasurement RateLow Batte

Page 43

i WARNING: To avoid electric shock, disconnect the test leads from any Isource of voltage before removing the battery door.I1.2.3.4.Disconnect the tes

Comments to this Manuals

No comments