• Safety • Operation • Maintenance • Español Owner’s Manual Auto-Ranging MultiMeter Model 82344 © Sears, Roebuck and Co
10 BATTERY INSTALLATION WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery/fuse cove
11OPERATING INSTRUCTIONS WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great
12AC VOLTAGE MEASUREMENTS WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets f
13AC/DC CURRENT MEASUREMENTS CAUTION: Do not make high current measurements on the 10A scale for longer than 15 seconds followed by a 15 minute cool
14RESISTANCE MEASUREMENTS 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive
15TEMPERATURE MEASUREMENTS WARNING: To avoid electric shock, disconnect test leads from any source of voltage before making a temperature measurement
16 DIODE MEASUREMENTS 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V/ /m
17MAINTENANCE WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery/fuse cover. WARNIN
18 REPLACING THE BATTERIES WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery cover.
19 TROUBLESHOOTING There may be times when your meter does not operate properly. Here are some common problems that you may have and some easy soluti
2TABLE OF CONTENTS Page Warranty 3 Safety Instructions 4 Safety Symbols 5 Control and Jacks 6 Symbols and Annunciators 6 Specifications 7 Batter
3ONE YEAR FULL WARRANTY ONE YEAR FULL WARRANTY ON CRAFTSMAN MULTIMETER If this CRAFTSMAN Multimeter fails to give complete satisfaction within one ye
4SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed
5SAFETY SYMBOLS This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the
6CONTROLS AND JACKS 1. LCD Display 2. DATA HOLD button 3. SELECT button 4. Function switch 5. Positive input jack 6. COM jack 7. 10A jack 8. Rubber b
7SPECIFICATIONS Function Range Accuracy 400.0mV ±(0.5% reading + 4 digits) 4.000V 40.00V 400.0V DC Voltage (V DC) 600V ±(0.8% reading + 4 digits)
8SPECIFICATIONS Function Range Accuracy 4.000nF Not specified 40.00nF 400.0nF 4.000F ±(3.0% reading + 10 digits) 40.00F Capacitance 100F Not Speci
9SPECIFICATIONS Diode Test Test current of 0.6mA maximum, open circuit voltage 1.5V DC typical Continuity Check Audible signal will sound if the re