SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Excessive dust in air 1. Leaking bag or hose connection 1. Check cellector bag connections.Check
Igouging at ends of board) collector hose connections
2. Collector bag leaks 2. Dust trapped under bag clamp or collector
bag not sealed on flange
Excessive fan noise 1. Large debris or piece of wood in 1. Turn collectoroff and let debris settle in
fan housing collector bag. Remove blade guard and
clear chamber
2. Loose fan 2. Open blade cover and tightenfan bolt
Motor overheats 1. Motor ovedoad 1. Reduce depth of cut
2. Improper motor cooling 2. Clean sawdustfrom motor
Trippingcircuitbreaker or 1. Motor ovedoad i1. Reduce depth of cut
fuses 2. Improper capacityof circuit 2. Use proper capacity circuit breaker or fuse
breaker or fuses
3. Dull blades 3. Replace blades
18
Comments to this Manuals