Craftsman 351.217040 Operator's Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Figure 6 - Functions of the Digital Scale
This scale uses a 1.55 volt battery cell (SR44). If it
needs replacing, slide off the battery cover and
insert the battery, with the positive pole of the bat-
tery facing out.
NOTE: After replacing a battery, the digital display set-
tings should be recalibrated.
BUTTON FUNCTIONS
ON/OFF/ZERO - Power and Zero Setting
Press ON/OFF/ZERO button no longer than three (3)
seconds to power on.
Press ON/OFF/ZERO button at least three (3)
seconds to shut off the digital display.
While in relative mode, press ON/OFF/ZERO (no
longer than three (3) seconds to set current position
as relative zero point.
While in absolute mode, press ON/OFF/ZERO (no
longer than three (3) seconds to set current position
as absolute zero point.
ABS - Relative/Absolute Modes
The scale is in absolute mode as soon as power is
turned on, and displays absolute zero. Moving the
planer table up and down begins absolute measure-
ment. Absolute measurement is usually set based
upon the distance from cutterhead to table.
Press ABS button (no longer than three {3} seconds)
to switch to relative mode. "INC" will appear on the
display. The value shown is in relative mode. Moving
the table up and down will now display relative mea-
surement.
MM/INCH - Millimeters/Inches
Pressing this button toggles back and forth between
standard and metric, and can be done at any time
without affecting saved settings.
HOLD - Maintains Data On The Display
Press this button to "freeze" a measurement on the
display; it will remain even if the table is moved.
Press HOLD again and it returns to normal
measurements.
SET - Preset a Value
Press SET; the indicator will flash "SET". Press and
hold the SET button and each digit flashes in turn.
When the digit you want flashes, release the SET
button.
Press SET button once (no longer than one {1}
second) and that digit will increase by one each time
SET is pressed. When finished, press and hold SET
button until indicator "SET" flashes, then press SET
again (no longer than one {1} second). The indicator
"SET" disappears and the value you just input is
displayed on the screen.
From this point on, any table movement will be
based off this setting. The setting will be kept in the
device's memory, even when the digital display is
turned off.
TOL - Tolerance Setting
Press TOL and an up-arrow indicator will appear, as
well as a flashing "SET" indicator. You can now
change the upper tolerance limit.
Hold down the TOL button and each digit flashes in
turn. When the digit you want flashes, release the
TOL button.
Press TOL button once (no longer than one {1}
second) and that digit will increase each time TOL is
pressed.
When finished, press and hold TOL button until
indicator "SET" flashes. While indicator "SET" is
flashing, press SET button to change the arrow to
the down-arrow indicator. You can now change the
lower tolerance limit in the same manner as you
changed the upper tolerance limit.
When finished setting the lower tolerance limit,
while indicator "SET" is flashing, press SET button
(no longer than one {1} second). The device is now
in tolerance measuring mode. When the up-arrow
indicator is displayed, it means the measured value
is beyond the upper limit. When the down-arrow
indicator is displayed, the measured value is below
the lower limit. When the display shows an "OK"
indicator, the measured value is within tolerance.
8
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 23 24

Comments to this Manuals

No comments