StatStatienTM
The StatStationTM displays the nominal load on generator
based on output frequency, it also has a built in maintenance
reminder.
WattageMonitor Operation
The display is two seven-segment LEDsthat provide an easy-
to-read indication of the amount of power being supplied by
the generator. The load monitor displays the generator's
output as a percentage.
As generator load increases,the display values will increase.
When the displayedvalues begin flashing, the user should
stop adding electrical loads to the generator.
If the power usage becomestoo high, the letters "OL" (for
Over Load)will flash on the display. The user should reduce
the amount of load attached to the generator.
Maintenance Reminder
The LEDwill display certain codes to alert you to check oil,
change oil, check or replaceair filter and check or replace
spark plug. The following codes will display:
"C1" Check oil at 8 hour increments
"C2" Changeoil at 50 hour increments
"C3" Check or replaceair filter at 25 hour increments
"C4" Check or replacespark plug at 100 hour increments
To take advantage of the StatStation "maintenance reminder"
capabilities, the user must press the resetbutton after
completing the maintenancecalled for in the displayedcode
(Cl, C2, C3, or C4). This results in a display of "Co" or "CA",
depending on how long the button is pressed:
1) "Co" - Pressingthe reset button once quickly will display
"Co"(clearing to zero). This will clear any maintenance
codes that have elapsed up to that point and they will
begin timing again from zero.
2) "CA" - Pressing and holding the reset button for
2 seconds will display "CA"(clearing all). This clears all
maintenancecodes, even if they have not yet reached
their service point, and they will begin timing again from
ze ro.
If nominal load and maintenancecodes appear
simultaneously, the LEDshall display, alternately, the
nominal load and code as follows:
The code will display for 3 seconds, then 1/2 second off. The
load will display for 6 seconds and then 1/2 second off.
ENGINEMAIHTENANCE
WARHIHG
f'_J Unintentionalsparking can result in fire or
electric shock.
WHENADJUSTINGORMAKINGREPAIRSTOYOURGENERATOR
* Disconnectthe sparkplugwire fromtile sparkplugandplace
thewire whereit cannotcontactsparkplug.
WHENTESTINGFORENGINESPARK
* Useapprovedsparkplugtester.
* DONOTcheckfor sparkwith sparkplugremoved.
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergentoils are acceptableif classified for service SF,SG,
SH,SJ or higher. DO NOTuse special additives.
Outdoor temperatures determinethe proper oil viscosity for
the engine. Usethe chart to select the best viscosity for the
outdoor temperature range expected.
oF
104 m __
86 __
68 -- w --_
32
14
-4
-22
°C
2O
_ m 0
L--J L--2o
;--#X_/_---30
* Below40°F(4°C)theuseof SAE30will resultinhardstarting.
** Above80°F(27°0)theuseof 10W30maycauseincreasedoil
consumption.Checkoil levelmorefrequently.
_ OTE:Synthetic oil meeting ILSACGF-2,API
certification mark and API serv,!cesymbol with
"SJ/CF ENERGYCONSERVING or higher, is an
acceptableoil at all temperatures. Use of synthetic oil
does not alter required oil change intervals.