CORDSETSANDRECEPTACLES
Useonly high quality, well-insulated, grounded extension
cords with the generator's 120 Volt electrical receptacles.
Inspectextension cords before each use.
Checkthe ratings of all extension cords before you use them.
Extensioncord sets used should be rated for 125Volt AC
loads at 20 Amps or greater for most electrical devices.
Some devices,however, may not require this type of
extension cord. Checkthe operator's manuals of those
devices for the manufacturer's recommendations.
,_ WARHIHG
_ verloaded electrical cords can overheat, arc, and
burn resulting in death,bodily injury,and/or
propertydamage.
* ONLYusecordsratedfor your loads.
, Followall safetieson electricalcords.
Keepextension cords as short as possible, preferably less
than 15 feet long, to prevent voltage drop and possible
overheating of wires.
120/240 Volt AC, 30 Amp, Locking Receptacle
Usea NEMAL14-30 plug with this receptacle.Connecta
4-wire cord set rated for 250 Volt AOloads at 30 Amps (or
greater). You can usethe same4-wire cord if you plan to
run a 120 Volt load.
4-WireCordSet
J
120 Volt AC, 20 Amp, Duplex Receptacles
Eachduplex receptacle is protected against overload by a
double pole rocker switch circuit breaker.
Useeach receptacleto operate 120 Volt AO,single-phase,
60 Hzelectrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Usecord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.
GEHERATORADAPTERCORDSET
The generator comes with a 25' generatoradapter cord set
designedto provide two sets of 120 Volt, 20 Amp outlets
from one 120 Volt, 20 Amp duplex receptacle.
(Neutral)
Y (Hot) | X (Hot)
NEMAL14-30 /--7I-7 Ground(Green)
This receptaclepowers 120/240 Volt A6, 60 Hz, single phase
loads requiring up to 5,600 watts of power (5.6 kW) at
23.3 Amps for 240 Volts or two independent 120 Volt loads
at 23.3 Amps each. The outlet is protected by a double pole
rocker switch circuit breaker.
NOTICE
Receptaclesmay be marked with rating value greater than
_ienerator out_
NEVERattemptto poweradevicerequiringmoreamperage
than generatoror receptaclecansupply.
DONOToverloadthe generator.SeeDon't OverloadGenerator.
The maximum load on each outlet is 20 Amps. The maximum
total load on both black wire outlets or white stripe wire outlets
is 20 Amps. If an extension cord is used with adaptercord set,
besure extensioncord is rated for 125V at 20 Amps.
NOTE:Followall safety precautions when connecting any
extension cord or deviceto the generator.