Customer Responsibilities
Before Daily
or after Every Every
each each 40 100 Yearly
use
use hours qours
Check Safety Valve @
Drain Tank @
Air Filter @(1) @
Air compressor pump intake
and exhaust valves @
1- more frequent in dusty or humid conditions
To Check Safety Valve
cycles automatically when power
is on, When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts,
Before servicing unit unplug or
disconnect electricam supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool,
To ensure efficient operation and
longer life of the air compressor,
a routine maintenance schedule
should be prepared and followed.
The following routine maintenance
schedule is geared to a unit in
a norma! working environment
operating on a daily basis. If
necessary, the schedule should be
modified to suit the conditions under
which your compressor is used. The
modifications will depend upon the
hours of operation and the working
environment. Compressor units in an
extremely dirty and/or hostile
environment wil! require a greater
frequency of all maintenance checks.
NOTE: See "Operation" section for
the location of controls.
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion,
1. Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1. Set the On/Auto/Off lever to "Off"
and unplug unit.
2. PutI the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
3. Remove the air tool or
accessory.
4. Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5. Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
condense in the air tank, If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture,
15-ENG A09711