Craftsman 152.217050 Operations Instructions Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
ADJUSTING TABLE GUBS
Gibs are internai mechanisms that take up any piay
between the base and the infeed and outfeed tames.
Precise gib adjustment is done at the factory and
shouid not require any further adjustments. However,
if adjustments are required, phase follow instructions
bebw.
Fig. 21-1
B A A C
2,
3,
4,
5,
WARNING: DISCONNECT JOINTER/PLANER
FROM POWER SOURCE.
Loosen each of the bck nuts (A) on the backside
of the infeed (B) and outfeed tames (C). See
Figure 21-1.
Loosen the infeed tame bck, bcated on the front of
the infeed tame and the outfeed tame thumbqock
screw, bcated on the back of the outfeed tame.
Turn aH set screws (D) in until they bottom out,
fingertight. Do not over-tighten set screws as this
wHi make raising and bwering tames difficuit.
See Figure 21-1.
Recheck piay in the table gibs. If table is difficult to
raise or lower, loosen set screws. If there is still too
much play in gibs, continue tightening set screws.
6. Tighten lock nuts without letting set screws turn.
CHANGUNG MOTOR VOLTAGE
MAKE CERTAIN the Jointer/Haner is disconnected
from the power source before working on motor.
Have a certified electrician make all electrical connec-
tions. All local and state codes must be maintained.
The motor supplied with the Jointer/PDner is a dual
voltage 120/240-voit, single phase motor. The motor is
wired from the factory for 120-voit operation. To change
to 240-voit operation for your Jointer/Haner, proceed
with the following instructions. It is also necessary to
replace the 120 volt plug, supplied with the Jointed
Planer, with a UL/CSA Listed plug (not included) suit°
able for 240 volts and the rated current of the motor.
The Jointer/Haner with a 240 volt plug should only be
connected to an outlet having the same configuration
as the plug. No adapter is available or should be used
with the 240 volt plug.
1, Make sure switch is OFF and disconnect power
cord from power source,
2, Remove the front panel and verify on the motor tag
that motor is dual voltage,
3. if motor tag states that it is dual voltage remove
junction box cover on motor.
4, Using wiring diagram on inside of junction box
cover, reconnect motor leads for 240-volt operation,
5, Replace junction box cover and reassemble front
panel,
6, Replace 120 volt plug with a UL/CSA Listed 240
volt plug rated for current of the motor,
7. The ON/OFF switch is a 4-pole switch and does not
need any modifications.