Checklist Before Starting Pump Motor
Review the unit’s assembly to ensure you have performed all of
the following.
1. Be sure to read Operator Safety and Operation before using
the electric pressure washer.
2. Check for properly tightened hose connections.
3. Check to make sure there are no kinks, cuts, or damage to
hoses.
4. Provide a proper water supply at an adequate flow (not to
exceed 100°F).
5. Plug electrical power cord into an electrical circuit rated for
120 Volts AC at 15 Amps that is properly installed in accor-
dance with all local codes and ordinances.
Servicing Of A Double-Insulated Appliance
In a double-insulated product, two systems of insulation are
provided instead of grounding. No grounding means is
provided on a double-insulated product, nor should a means for
grounding be added to the product. Servicing a double- insulated
product requires extreme care and knowledge of the system, and
should be done only by qualified service personnel. Replacement
parts for a double-insulated product must be identical to the
parts they replace. A double- insulated product is marked with
the words “DOUBLE INSULATION” or “DOUBLE INSULATED.”
The symbol means DOUBLE-INSULATED APPLIANCE.
Ground Fault Circuit Interrupter Protection
This pressure washer is provided with a ground-fault circuit- in-
terrupter (GFCI) built into the plug of the power supply cord. This
device provides additional protection from the risk of electric
shock. Should replacement of the plug or cord become neces-
sary, use only identical replacement parts that include GFCI
protection. Do not operate pressure washer if GFCI is not working
HOW TO USE YOUR PRESSURE WASHER
If you have any problems operating your pressure washer, please
call the pressure washer helpline at 1-866-902-9690.
How to Start Your Electric Pressure Washer
1. Place the electric pressure washer near an outside water
source capable of supplying water at a flow rate greater
than 3 gallons per minute (11.4 liters) and no less than 20
psi (1.38 bars) at the electric pressure washer end of garden
hose. DO NOT siphon supply water.
2. Connect garden hose to water inlet.
3. Check that high pressure hose is tightly connected to spray
gun. See Connect Hoses and Water Supply for illustra tions.
NOTICE DO NOT run the pump without the water supply con-
nected and turned on. Damage to equipment resulting from
failure to follow this instruction will void warranty.
4. Turn ON water, point gun in a safe direction, press trigger
lock button and squeeze trigger to purge pump system of air.
5. Remove any dirt or foreign matter from spray tips. Install
desired wand onto spray gun. See Connect Hoses and Water
Supply and How to Use Spray Tips for details.
6. Turn the master ON/OFF switch (A) to the OFF (0) position by
turning dial counterclockwise.
WARNING Risk of eye injury. Spray could splash back
or propel objects resulting in serious injury. Always
wear indirect vented (chemical splash) safety goggles
marked to comply with ANSI Z87.1 when using or in vicinity
of this equipment. NEVER substitute safety glasses or dry-
condition goggles for indirect vented safety goggles.
OPERATION
A
8
Comments to this Manuals