Add Gasoline
,_ WARNING! Never fill fuel tank indoors. Never
fill fuel tank when engine is running or hot. Allow
unit to cool for two minutes before refueling. Do
Not light a cigarette or smoke when filling the
fuel tank.
,_ WARNING! Do Not overfill the fuel tank.
Always leave room for expansion.
Use regular UNLEADED gasoline with the
generator engine. Do Not use premium gasoline.
Do Not mix oil with gasoline.
Clean area around fuel fill cap, remove cap.
Slowly add unleaded regular gasoline to fuel tank.
Be careful not to overfill. Allow about 1/2" of tank
space for fuel expansion, as shown here.
1/2" Air Space Tank
Fuel
Install fuel cap and wipe up any spilled gasoline.
IMPORTANT: It is important to prevent gum deposits
from forming in fuel system parts such as the
carburetor, fuel hose or tank during storage. Alcohol-
blended fuels (called gasohol, ethanol or methanol)
can attract moisture, which leads to separation and
formation of acids during storage. Acidic gas can
damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. See
"Storage" on page 16. Never use engine or carburetor
cleaner products in the fuel tank as permanent
damage may occur.
TO START THE ENGINE
,_ WARNING! Never start or stop engine with
electrical devices plugged into the receptacles
AND devices turned ON.
Disconnect all electrical loads from the generator. Use
the following start instruction steps by numerical order:
1. Make sure the Idle Control switch is in "Off"
position.
r
IDLE
OFF
position
2. Turn the fuel valve to the "On" position.
_FUEL TAN_
Fuel Shutoff Valve
3. Set the Run/Stop switch to "Run" position.
4. Place the choke lever in the "Full" choke position.
FULL RUN
//
5B. Grasp the recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly one time only
to start engine.
If engine starts, proceed to step 7.
If engine fails to start, proceed to step 6.
6. Move the choke lever to "Half" choke position, and
pull recoil handle twice.
If engine fails to start, repeat steps 4 thru 6.
7. Move choke lever to "Run" position. If engine
falters, move choke lever to "Half" choke position
until the engine runs smoothly, and then to "Run"
position.
NOTE: If engine starts after 3 pulls, but fails to run for
more than 10 seconds, check for proper oil level in
crankcase. This unit is equipped with a Low Oil
Pressure Shutdown System (see below).
IMPORTANT: Do Not overload the generator. Also,
Do Not overload individual panel receptacles. These
outlets are protected against overload with push-to-
reset-type circuit breakers. If amperage rating of any
circuit breaker is exceeded, that breaker opens and
electrical output to that receptacle is lost. Read "Don't
Overload the Generator" on page 11 carefully.