Craftsman 919.167462 Owner's Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding pages
and pe_orm scheduled
maintenance as necessary.
2. Set the On/Auto/Off lever to
"OFF" and unplug unit.
3. Turn the regulator
counterclockwise and set the
outlet pressure to zero.
4. Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6. Drain water from air tank by
opening drain valve on bottom
of tank.
I_ Risk of Bursting.
Water will
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
7. After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
8.
g.
Protect the electrical cord and air
hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor handle.
Store the air compressor in a
clean and dry location.
D30050 18_ ENG
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 47 48

Comments to this Manuals

No comments