Owner's ManualI CRRFTglVlRN°IPermanently LubricatedTank MountedAiR COMPRESSORModel No.919.152144= Safety Guidelines= Assembly= Operation= Mainten
HOW TO SET UP YOUR UNiT iMPORTANT: The outlet being usedLocation of the Air CompressorLocate the air compressor in aclean, dry and well ventilated are
Extension CordsUsing extension cords is notrecommended. The use of extensioncords will cause voltage to dropresulting in power loss to the motorand ov
Know Your Air CompressorREAD THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATINGYOUR UNIT. Compare the illustrations with your unit to familiar
Air Compressor Pump (not shown):Compresses air into the air tank.Working air is not available until thecompressor has raised the air tankpressure abov
Before Each Start=Up:1. Place On/Auto/Off lever to"OFF" and close air regulator.2. Pull regulator knob out, turncounterclockwise until it st
Customer ResponsibilitiesBefore Dailyeach or aftereachuseuseCheck Safety Valve •Drain Tank •Risk of UnsafeOperation. Unit cyclesautomatically when pow
ALL MAINTENANCE AND REPAIROPERATIONS NOT LISTED MUSTBE PERFORMED BY A TRAINEDSERVICE TECHNiCiAN.Risk of UnsafeOperation. Unitcycles automatically when
To Replace Regulator1. Release all air pressure from airtank. See "To Drain Tank" in theMaintenance section.2,3.Set the On/Auto/Off lever to
Before you store the air compressor,make sure you do the following:1. Review the "Maintenance"section on the precedingpages and perform sche
Risk of Unsafe Operation. Unit cycles automatically whenpower is on. When servicing, you may be exposed tovoltage sources, compressed air, or moving p
WARRANTY ... 2SPECiFiCATiON CHART ... 3SAFETY GUiDELiNES ...
PROBLEMPressure readincon the regulatedpressure gaugedrops when anaccessory isused.Knocking Noise.Compressor isnot supplyingenough airto operateaccess
PROBLEMRegulator willnot shut off airoutlet.Motor will notrun.CAUSE CORRECTIONDamaged regulator. Replace.Motor overload protectionswitch has tripped.T
Air Compressor Model Number 9t9.152t441\4 15 \\,\\5\2611108\sA02265 22-ENG
Air Compressor Model Number 919.152144KEYNO. PART NUMBER DESCRiPTiON1 Z-D24671 Tank2 33T-108 Recess Rubber Bumper (3 used)3 91895680 Screw (3 used)4 S
Air Compressor Model Number 919.152144237Torque30-45in.dbs. 13®18\\5111-211-176 Torque3 45-55\\.192OHand TightTorque10 in.qbs. MaxA02265 24-ENG
Air Compressor Model Number 919.152144KEYNO. PART NUMBER DESCRiPTiON1 CAC-1320 Shroud (left)2 D25735 Shroud (right)3 D25877 Head4 CAC-1212 Tube Seal5
GARANTJA ... 26CUADRO DE ESPECIFICACIONES ... 27DEFINICION
Modelo N°MAx. HP desarrolladoPotencia de trabajoDi_metro interiorCarreraVoltaje-corriente manof_sicaCircuito minimo requeridoTipo de fusibleAcci6n ret
GUARDE ESTAS INSTRUCCIONESLa operaci6n o el mantenimiento inadecuados de este producto podrianocasionar serias lesiones y dafios a la propiedad. Lea y
H ZqADVERTENCIA: Riesgo de E×plosibn I._1Tanque de aire: las siguientes condiciones podrfan, causar el debilitamiento del tanque, ydeterminar su explo
Model No. 919,152144Max. Developed HP 2Running HP 1Bore 47.625Stroke 31.75Voltage-Single Phase 120VMinimum Branch Circuit Requirement 10 ampsFuse Type
ADVERTENCIA:RiesgodeDescarga El_ctrica I _ Iqu_ puede occurrir c6mo prevenirloSu compresor de aire esta accionado por Jamas opere el compresor a la in
ADVERTENCIA:Riesgo de Quernaduras I_1!_1gU_ puede occurrir c6mo prevenirloTocar el metal expuesto tal como el cabezal Jam_s toque partes de metal expu
ADVERTENCIA:Riesgo de Serias Lesiones o Da_os a la Propiedad al JR7Transportar el Compresor(Fuego, inhalaci6n, daSo a la euperficie de vehiculos)qu_ p
Familiarfcese con los siguientes terminos,antes de operar la unidad:CFM: (Cubic feet per minute) Pies cLibicospor minuto.SOFM: (Stardard cubic feet pe
COMO PREPARAR LA UNIDAD 2. AsegOrese de que el tomacorrienteUbicaci6n del compresor de aireUbique al compresor de aire en unazona limpia, seca y bien
Cables de extensi6n el_ctricaNo so recomienda la utilizaci6n de cablesde extensi6n electrica. El uso de cablesde extensi6n el_ctrica originara unaca[d
Conozca su compresor de aireLEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DEOPERAR LA UNIDAD. Compare las ilustraciones contra su un
Bomba de cornpresi6n del aire (nomostrada): Comprime el aire dentro deltanque. El aire de trabajo no se encuentradisponible hasta que el compresor hay
Antes de cada puesta en marcha:1. Coloque el interruptor On/Auto/Off en laposici6n "OFF" y cierre el regulador deaire.Tire de la perilla del
Responsabilidades del clienteAntesde Diadamentecada s luegodecadaus(}useVerifique la v_lvula de seguridad •Drenaje del tanque •Riesgo deOperacibnInseg
Save these instructionsImproper operation or maintenance of this product could result in serious injury andproperty damage. Read and understand all wa
TODO TIPO DE MANTENIMiENTOY OPERACIONES DE REPARACIONNO MENOIONADOS, DEBERAN SEREFECTUADOS PeR PERSONAL TECNICOESPEClAMZADO.Riesgo deOperacibnInsegura
Para reemplazar el regulador1. Libere toda la preei6n del aire del tanque.Yea "Drenaje del tanque" en la eecci6n"Mantenimiento".2.
Antes de guardar su compresor de aire,asegOrese de hacer Io siguiente:1. Revise la secci6n "Mantenimiento"de las paginas precedentes y ejecu
Riesgo de Operaeibn Insegura: La unidad arrancaautom_ticamente cuando est_ enchufada. AI hacer elmantenimiento, el operador puede quedar e×pueste a fu
PROBLEMALa lectura de lapresiOn sobre unman6metro (siviene equipadocon 6ste)desciende cuandose utiliza unaccesorio.El compresorno estasuministrandosuf
PROBLEMAEl motor nofunciona.CAUSAFusible fundido; interruptorautomatico del circuito disparado.El cable de extensidn electricatiene una Iongitud o cal
A02265 46-SP
Repair Protection AgreementsCongratulations on making a smartpurchase. Your new Craftsman '_productis designed and manufactured for yearsof depen
WARNING: Risk of Bursting I_1Air Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion and could
WARNING: Risk of Electrical ShockHow To Prevent itWhat Could HappenYour air compressor is powered byelectricity. Like any other electricallypowered de
WARNING: Risk of Burns I_1What Could Happen How To Prevent itTouching exposed metal such as thecompressor head or outlet tubes, canresult in serious b
WARNING: Risk of Electrical ShockHow To Prevent itWhat Could HappenYour air compressor is powered byelectricity. Like any other electricallypowered de
Become familiar with these termsbefore operating the unit.CFM: Cubic feet per minute.SCFM: Standard cubic feet perminute; a unit of measure of airdeli
Comments to this Manuals